Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

Specifications
Communications
Connector
Cable BPL3/PL Sensor – Interface:
3 × wires via clamps (back):
2 × wires for DC power & communication: broadband over power line (BPL) and 1 × wire for functional earth

Interface Mounting:
EDGE-rack mountable
Ethernet
2 × RJ45 Ethernet connectors (10/100 Mbit/s auto switching)
Input
4 × input contacts via EDGE connector (back, pins 1, 2, 3, 10)
4 × input LEDs (front, green)
Note: maximum 20 extra detection outputs can be added via maximum five 4 I/O USB units
Output
Detection Outputs:
64 × BIU output states via Port-1 connector at front (SDLC) to TS-2/ATC controller
128 × SIU output states via C12S connector at front (SDLC) to ATC controller
4 × optical coupled dry contacts via EDGE connector (back, pins F/H, W/X, S/T, Y/Z) to TS-1 controller
Imax = 50 mA, Umax = 48 V DC
Close on event or open on event (setting in software)
4 × output LEDs (front, green)
Detection output 1 to 4 and common detection output 1 to 4

Error Outputs:
1 × optical isolated switch component via EDGE connector (back, pins J/K) - Imax = 50 mA, Umax = 48 V DC
Open on event (hardware output)
8 × BPL3/PL sensor status LEDs (front, bicolor green/red)
Error output and common error output

Function of Error Output:
Error output active = error in TI BPL3 EDGE B&SIU or power supply down, or
Error output active = error in 4 I/O USB with output(s) assigned (e.g. no communications), or
Error output active = error in corresponding BPL3/PL sensor (e.g. no communications)
Electrical
Power
Power IN:
12 V DC to 60 V DC, via EDGE connector (back, pins A/B, polarity sensitive), power button and LED (front, bicolor green/red)
Separate 24 V DC to 48 V DC via EDGE connector (back, pins D/E) for BPL3/PL sensors
Note: 48 V DC on pins D/E recommended when multiple BPL3/PL sensors and/or long cable distances

Power OUT:
Idem power IN, via EDGE connector (back, pins P/R, polarity insensitive)
Note: BPL3 communications to BPL3/PL sensors added at interface level

Power Consumption:
Interface only: typical ≤5 W (6 W peak at start-up)
Maximum, interface with periphery: <100 W @ 24 V DC

Current Consumption:
Interface only: typical ≤210 mA @ 24 V DC
Maximum, interface with periphery: <4 A @ 24 V DC
Environmental
Operating Temperature Range
NEMA II specs: -34°C to 74°C (-29.2°F to 165.2°F)
Mechanical
Dimensions
H × W × D: 115 mm × 59 mm × 191 mm (4.53 in × 2.32 in × 7.52 in) Standard US EDGE rack height & depth; width = double slot
Weight
450 g (1 lb)
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

TI BPL3 EDGE B and SIU INTERFACE